Advice
A Guide To iAquaLink Error Codes
How To Read iAquaLink Error Codes
Find out the different iAquaLink error codes and determine what they mean and the best course of action for when you encounter them!
LEVEL 1
| 120 | Low cell current in forward direction – check DC cord, clean cell if necessary or replace cell |
| 121 | Low cell current in reverse direction, same as 120 above |
| 123 | Low to no current at cell – check DC cord, clean cell or replace if necessary |
| 124 | High current indicated at the cell – this usually means a bad PIB |
| 125 | Cell needs to be cleaned or replaced |
| 126 | Low current in forward direction and VAC input voltage below 100/200 VAC - check input voltage, transformer and PIB voltages |
| 127 | Low current in reverse direction and VAC input voltage below 100/200 VAC - check input voltage, transformer and PIB voltages |
| 144 | Low Salinity (below 2.0 gpl) - indicates the pool needs salt added |
| 145 | High Salinity (above 4.0 gpl) - indicates pool needs to be diluted |
| 170 | PIB service condition indicated and is usually caused by low incoming AC voltage - check transformer voltages or for faulty sensors |
| 171 | PIB service condition - indicates board needs to be replaced |
| 172 | Flow sensor service - clean sensor, check for damage and replace if necessary |
| 173 | Low VAC input voltage and on-board power supply is not regulated - make sure unit is wired with the proper voltage |
| 174 | Pool temperature is too high for operation of AquaPure® (i.e. > 108°F) |
| 175 | Flow sensor air lock condition or very low salinity |
LEVEL 2
| 180 | Heated sensor element not heating (generates 172 code) |
| 181 | Flow sensor temperature sensor failure (generates 172 code – Flow sensor service) |
| 182 | Salinity Sensor sees less than 0.2 gpl of salt, either no salt in pool or sensor air locked (generates 175 code – Flow sensor air lock) |
| 183/186 | Flow salinity sensor temperature probe error codes. They generate 172 codes which indicate flow sensor service is required |
| 187 | PIB power supply either too low or too high (Low input voltage code 173 if Level II code 188 is present) (code 170 if 188 is not present). |
| 188 | VAC input voltage is too low (generates 173 code if Level II code 187 is present) |
| 189 | Relay not conducting in the forward direction (generates 171 code - PIB service) |
| 190 | Relay not conducting in the reverse direction (generates 171 code - PIB service) |
| 191 | High cell current (at upper limit of A/D converter) and cell voltage below 19V (generates 170 code PIB service) |
| 192 | High cell current and cell voltage below 19V (generates 171 code – PIB service). |
| 193 | Measured significant cell current when SCRs were turned off (generates 170 code – PIB service). |
| 194 | Cell Current is 85% lower than desired and cell voltage above 19V (generates 125 code - Cell dirty or needs replacement). |
| 195 | Salinity invalid due to out of range measurements caused by PIB error (generates 170 code – PIB service). |